Double-disc butterfly valve features double sealing rings on its butterfly plate, providing excellent sealing performance for both inlet and outlet.

 

This butterfly valve incorporates a middle chamber water passage function, further enhancing the sealing effect. It is highly suitable for handling water and gas media and is often used as a vacuum valve. This design has been widely applied by SHOWA in Japan and implemented in the Shanghai Shidongkou Power Plant. However, during system design, caution must be taken to prevent water from flowing back into the steam turbine when the valve is opened to ensure the safety of the blades.

 

The three-way metal-sealed butterfly valve is primarily used to change the flow direction of the medium. The hydraulically controlled butterfly valve (hydraulic slow-closing check butterfly valve) operates through a hydraulic system for opening and closing. When opening, the hydraulic system lifts the valve and simultaneously raises a weight attached to the arm. For closing, the solenoid valve directs the hydraulic oil back to the tank, allowing the weight to slowly close the valve. This design enables the butterfly valve to close in stages, effectively reducing the impact of water hammer. Furthermore, the valve can be customized based on different signal sources for special applications such as preventing pipeline ruptures.

 

Quick-closing or quick-opening butterfly valves do not significantly differ from conventional butterfly valves in principle but focus on high-speed operation requirements. They are usually equipped with high-speed response mechanisms to ensure rapid opening or closing actions. As quick-closing valves play a crucial role in many applications, their reliability is of utmost importance, and it must be ensured that they do not get stuck and fail to close.

 

Two-step action butterfly valves feature a unique design where the butterfly plate first rotates 90° and then moves to press against the sealing surface. This complex action design makes them relatively rare in practical applications. Nevertheless, two-step action butterfly valves offer significant advantages in certain special situations. For example, the United States manufactured gear-rack-driven two-step action butterfly valves in the 1970s and 1980s for naval applications. These valves are characterized by their unique action design, where the butterfly plate initially rotates 90° and then moves to press against the sealing surface. Although this design is relatively uncommon in practical applications, it has distinct advantages in specific scenarios.

 

A related type of two-step action butterfly valve is the linkage mechanism butterfly valve. This valve can be seen as an extension of the two-step action butterfly valve, with a flat sealing surface that facilitates good sealing performance. However, in high-pressure environments, this valve requires a larger opening torque, making it more suitable for vacuum systems, low-pressure gas systems, or as a high-temperature valve. One design of a four-linkage mechanism butterfly valve features an innovative linkage mechanism that ensures stable sealing performance even in high-pressure environments. Although this valve requires a larger opening torque, it is particularly suitable for vacuum systems, low-pressure gas systems, and can also be used as a high-temperature valve to meet various industrial needs.

 

Another design of the four-linkage mechanism butterfly valve incorporates a long-neck structure to prevent temperature transfer to the packing. In high-temperature environments, the long-neck section is equipped with heat sinks, while in low-temperature environments, insulation plates are installed to reduce cold loss. Clearly, both high-temperature and low-temperature valves have strict material selection requirements.

 

In addition, butterfly valves for nuclear power plants have also garnered significant attention. Due to their compact structure, simplicity, lightweight, rapid switching, and high flow coefficients, they are widely used in various systems within nuclear power plants, including process systems, circulating water systems, ventilation systems, and more. On the other hand, the selection of regulating butterfly valves is also crucial. Although the regulating characteristics of butterfly valves approximate an equal percentage, making them suitable for regulation, it should be noted that their regulating performance is poor at small openings, which can easily lead to cavitation, erosion, vibration, and noise. Therefore, it is generally not recommended to use them for regulation and throttling at small openings (less than 15° to 20°). When selecting butterfly valves, various factors should be comprehensively considered, including flow characteristics, sealing types, material selection, etc., to ensure that the selected butterfly valve can meet specific engineering requirements and safety standards.

 

Regarding the selection of vacuum butterfly valves, they are divided into two types: rubber soft seals and metal hard seals, with structures that can be centerline, eccentric, or lever types. For applications requiring high vacuum levels, soft seals are usually chosen; if temperature resistance is required, metal seals are selected. To ensure optimal performance, components should be finely machined with good surface roughness and cleanliness, and it is strictly prohibited to apply paint or ordinary antirust oil; only vacuum grease should be used.

 

The selection of the butterfly valve's diameter is primarily based on the medium flowing through the valve, as well as the flow rate or velocity. For example, for liquids, the flow velocity should generally not exceed 5 m/s, with a maximum of 7 to 8 m/s. The economic flow velocity range for water is 2 to 3 m/s, while for low-pressure gases, a flow velocity of 2 to 10 m/s is recommended, and for medium-pressure gases, it is 10 to 20 m/s. For steam, the recommended flow velocity is 20 to 40 m/s for low-pressure steam, 40 to 60 m/s for medium-pressure steam, and 60 to 80 m/s for high-pressure steam. It is worth noting that sometimes, in order to reduce pressure loss, a larger valve may be selected to lower the flow velocity. However, this approach is not suitable for small flow regulation scenarios.

 

Additionally, when the fluid passes through an area with very low absolute pressure within an extremely short period of time, cavitation may occur. This is due to the sudden condensation of vapor bubbles in the fluid as they enter a higher-pressure area, leading to bubble collapse or implosion. This implosion can generate flow velocities as high as 110 m/s and accompany high pressures of 50 MPa, causing impact damage to the walls. To avoid the occurrence of cavitation, a series of measures can be taken, such as controlling the flow velocity, introducing atmospheric air into the low-pressure area, or reducing the pressure difference.

 

When the pressure difference across the valve is less than 1.5 MPa, even if cavitation occurs, the damage to the material is not severe, so no special measures are required. From a material perspective, generally speaking, the harder the material, the stronger its resistance to cavitation. When the butterfly valve does not produce cavitation, its cavitation coefficient σ should typically be greater than or equal to 2.5.