Fire Signal Butterfly Valve | DN50-400 Supervisory Switch Factory

Fire Signal Butterfly Valve | DN50-400 Supervisory Switch Factory
Details:
Fire Signal Butterfly Valve — specialized fire-protection signal butterfly valve; disc rotates 90° on-off, high-precision travel switches convert real-time open/close/intermediate status to electrical signals (NO/NC) to fire control room, optional encoder 4-20mA analog remote visual monitoring; alarm on accidental close/block/failure. Fast: manual ≤3s, electric 1-5s. Compact (1/3–1/2 gate-valve length, light, narrow ceiling/pipe-shaft/garage). Straight-through low resistance — ensures sprinkler/hydrant pressure/flow. EPDM/NBR/PTFE/Viton seat, bidirectional zero leakage, life 8–12yr. Ductile iron/cast steel/SS304/316 body; ductile iron plastic-coated/SS disc; SUS410/316/duplex stem. DN50–400 (2"–16"), PN10/16/25 (150LB/JIS 5K/10K), -10~80°C. Flange/wafer/groove. Manual(handle/worm gear)/electric/pneumatic/electro-hydraulic. GB/T 5135.6-2018, API 609, BS 5155, DIN 3202, ISO 5752. Fire water (sprinkler/hydrant), oil, gas. Sprinkler zonal control, hydrant systems, high-rise/commercial/malls/hotels/hospitals, factories/warehouses/power/chemical, tunnels/airports/stations. Fire red, modular signal component. 18-month warranty, OEM/ODM — reliable fire-signal supervisory butterfly valve for fire protection water systems.
Send Inquiry
Add To Inquiry
Download
Description
Technical Parameters

Product Introduction

 

A Fire Signal Butterfly Valve is a specialized fire-protection valve that integrates a butterfly valve's efficient on-off performance with an intelligent signal feedback (supervisory switch) function - a circular disc rotates 90° to open/close fire water flow, and high-precision travel switches + linkage mechanism convert the valve's real-time open/close/intermediate status into electrical signals (NO/NC switch signals, or optional 4-20mA analog via encoder) and transmit them to the fire control room/center for remote visual monitoring and automatic alarm - if the valve is accidentally closed, blocked, or fails, the signal change triggers an alarm in time to avoid fire safety hazards - with fast operation (manual ≤3s, electric 1-5s), compact structure (body length only 1/3-1/2 of same-DN gate valve, light, for narrow spaces), straight-through low flow resistance (ensures sprinkler/hydrant pressure/flow), EPDM/NBR/PTFE/Viton soft seat bidirectional zero leakage, 8-12 year service life, flange/wafer/groove connection, manual (handle/worm gear)/electric/pneumatic/electro-hydraulic drive, DN50-400 (2"-16"), PN10/16/25, -10~80°C, fire red coating, GB/T 5135.6-2018 fire signal butterfly valve standard - a reliable, code-compliant, supervisory-signal butterfly valve for fire protection water systems. The core highlights are: (a) Fire protection specialized: designed specifically for fire water supply systems (not general industrial) - meets GB/T 5135.6-2018 (Chinese national standard for fire signal butterfly valves), fire red coating, fire water media (-10~80°C), reliable for fire emergency; (b) Signal feedback (supervisory switch): the key differentiator from ordinary butterfly valves - high-precision travel switches (micro switches) + mechanical linkage with valve stem/disc - when disc reaches fully open, fully closed, or intermediate positions, switches activate and output electrical signals (NO/NC - normally open/normally closed contacts) to fire alarm control panel (FACP); optional encoder outputs 4-20mA analog for precise position/remote visual monitoring on SCADA/BMS; (c) Remote monitoring + alarm: fire control room can remotely see valve status (open/closed) without manual site inspection - critical for fire safety (ordinary valves require manual check, easy to miss); if valve accidentally closed (e.g., someone turns it, maintenance forgot to reopen), blocked (debris), or fails, signal changes → alarm triggers (buzzer/indicator on FACP) - prevents "valve closed during fire" disaster; (d) Fast operation for emergency: disc 90° rotation - manual ≤3 seconds (worm gear/handle), electric 1-5 seconds - quickly opens water supply during fire emergency (gains valuable firefighting time), quickly closes for zonal water cut-off during maintenance; (e) Compact + space-saving: butterfly valve body length only 1/3-1/2 of same-DN gate valve - much shorter, lighter; ideal for narrow spaces (ceilings, pipe shafts, underground garages, mechanical rooms) common in high-rise buildings; (f) Low flow resistance: straight-through flow, fully open disc parallel to flow - resistance far lower than gate/globe - minimizes pressure loss, ensures sufficient water pressure/flow at end sprinklers/hydrants (critical for fire suppression - low pressure = ineffective sprinklers); (g) Reliable soft sealing: EPDM (water/weathering, ≤120°C), NBR (oil/water), PTFE (chemical/corrosive), Viton (high-temp/oil) - elastic, aging-resistant, water-resistant; disc + seat close fit = bidirectional zero leakage (no water waste, maintains system pressure); (h) Durable materials: body ductile iron (GGG40, standard fire valve), cast steel (WCB, higher pressure), stainless SS304/316 (corrosive); disc ductile iron with plastic coating (corrosion-resistant, smooth, low torque) or stainless SS304/316; stem SUS410 (13Cr, general), SUS316 (corrosion), duplex stainless (high strength/corrosion); (i) Multiple connections: flange (rigid, high pressure, easy remove), wafer (compact/light, clamped between flanges), groove (grooved) (fast install with roll-groove pipe + clamp, common in fire sprinkler systems - Victaulic style); (j) Multiple drives: manual handle (small DN), worm gear (larger DN, labor-saving, self-locking), electric (remote/automated, fast), pneumatic (fast, hazardous), electro-hydraulic (high torque, large DN); (k) Modular signal component: signal switch/encoder is modular - can be disassembled/replaced without removing the entire valve (easy maintenance, low downtime); (l) Wide size/pressure: DN50-400 (2"-16"), PN10/16/25 (1.0/1.6/2.5MPa, 150LB, JIS 5K/10K) - covers fire system sizes; (m) Temp: -10~80°C (fire water range - prevents freezing, handles warm water); (n) Media: water (primary - fire water), oil, gas; (o) Standards: GB/T 5135.6-2018 (fire signal butterfly valve - mandatory for Chinese fire systems), API 609, BS 5155, DIN 3202, ISO 5752; (p) Test: strength 1.5×PN, seal 1.1×PN; (q) Applications: automatic sprinkler systems (zonal control valve, alarm valve group front control, end test device control), fire hydrant systems (main pipe, branch pipe, fire pump outlet), high-rise buildings/large venues (residential, commercial, malls, hotels, hospitals), industrial/commercial facilities (factories, warehouses, power plants, chemical plants), other fire systems (tunnels, airports, railway stations). This is the reliable fire-signal supervisory butterfly valve solution for modern fire protection water systems.

The signal feedback (supervisory switch), fast emergency operation, compact space-saving design, low flow resistance for fire water pressure, bidirectional zero-leak soft sealing, multiple connections/drives, and fire-code compliance make this valve a specialized fire-protection supervisory butterfly valve - distinct from general industrial butterfly valves - designed specifically for fire water supply systems where remote status monitoring, fast emergency response, code compliance, and reliable water delivery are critical. Compared to other butterfly valves: (a) vs Electric Flange Butterfly Valve (previous product): that one is general industrial electric butterfly - electric actuator, on-off/regulating 4-20mA, large-bore DN50-2000, soft/hard seal, -29~550°C, general industrial (water treatment/petrochemical/power/metallurgy); this one is fire-specialized signal butterfly - core = signal feedback/supervisory switch (not electric actuation primary), manual primary (worm gear/handle) + optional electric, DN50-400 smaller, soft seal only (EPDM/NBR/PTFE/Viton), -10~80°C fire water, GB/T 5135.6-2018 fire standard, fire red, flange/wafer/groove, for fire sprinkler/hydrant - fire-specific vs general industrial; (b) vs ordinary butterfly valve (no signal): ordinary butterfly has no signal feedback - requires manual site inspection (can miss closed valve, dangerous for fire); this one has supervisory switch - remote monitoring + alarm (code-required for fire systems in many regions); (c) vs fire signal gate valve: fire signal gate valve is gate-type (multi-turn, slow, bulky/heavy, long body); this one is butterfly - 90° fast, compact/short/light, better for narrow spaces, lower cost at larger DN - butterfly preferred for modern fire systems (especially high-rise/narrow); (d) vs wafer butterfly valve: this one offers flange/wafer/groove (groove = grooved coupling connection, very common in fire sprinkler - fast install); (e) vs general signal valve: this is butterfly-type signal valve (not gate/globe/ball) - compact/fast/low-cost. Signal feedback principle detailed: (a) travel switches (micro switches): mounted on gearbox/indicator, mechanically linked to valve stem via cam/gear; (b) when stem rotates (disc opens/closes), cam rotates and activates/deactivates micro switches at preset positions (fully open, fully closed, sometimes intermediate); (c) switches output dry contacts - NO (normally open) and NC (normally closed) - wired to fire alarm control panel (FACP) or building management system (BMS); (d) FACP monitors contact status - if valve open = NO closed (or NC open), if closed = opposite; (e) supervisory signal: in fire systems, valve status is a supervisory signal (not alarm) - indicates "valve not in normal open position" - FACP shows supervisory alarm (distinct from fire alarm); (f) optional encoder: potentiometer/encoder tracks stem angle 0-90° → outputs 4-20mA analog (4mA=closed, 20mA=open) - precise position, remote visual on SCADA; (g) alarm conditions: valve closed when should be open (supervisory alarm), valve not responding (fault), intermediate position (partial - may indicate tampering/maintenance); (h) code requirement: many fire codes (NFPA 13, GB 50084, EN 12845) require supervisory switches on control valves in sprinkler systems - to prevent accidental valve closure (a leading cause of sprinkler system failure). Why signal feedback is critical for fire: (a) #1 cause of sprinkler system failure = control valve accidentally closed (during maintenance, tampering, negligence) - when fire occurs, no water reaches sprinklers; (b) supervisory switch = remote monitoring - FACP immediately alerts if valve closed - prevents this failure; (c) code-mandated: NFPA 13 requires supervisory devices on all control valves; GB 50084 (Chinese sprinkler code) requires signal valves; (d) this valve = code-compliant signal butterfly valve. Fast operation for fire emergency: (a) fire requires immediate water - fast valve operation critical; (b) butterfly 90° = fast (manual ≤3s with worm gear, electric 1-5s); (c) gate valve multi-turn = slow (30-60s+ for large DN) - too slow for emergency; (d) butterfly preferred for fire systems. Compact for high-rise/narrow spaces: (a) high-rise buildings have limited space - pipe shafts, ceilings, mechanical rooms; (b) butterfly valve short body (1/3-1/2 gate length) + light = fits narrow spaces; (c) gate valve long/tall = doesn't fit; (d) butterfly dominant in modern high-rise fire systems. Low flow resistance for sprinkler pressure: (a) fire sprinklers require minimum pressure/flow at end of system (e.g., 0.05 MPa at remote sprinkler); (b) high resistance valves = pressure loss = insufficient sprinkler pressure = ineffective fire suppression; (c) butterfly valve low resistance (K~0.2-0.5) = minimal pressure loss = ensures end pressure; (d) gate valve also low resistance but bulky; (e) butterfly = low resistance + compact ideal. Grooved connection for fire sprinkler: (a) grooved (grooved coupling): pipe ends roll-grooved, valve has grooved ends, coupling (clamp) with gasket connects - very fast installation (no welding/threading), no fire risk during install, easy disassembly; (b) dominant in fire sprinkler systems (Victaulic style); (c) this valve offers grooved connection - ideal for sprinkler; (d) flange for high pressure/main pipe, wafer for compact, groove for sprinkler branch. Fire red coating: (a) fire valves are painted red (fire safety color code) - easy identification in emergency; (b) ductile iron body + epoxy red paint (corrosion-resistant, durable); (c) some regions require red for fire valves. Drive options for fire: (a) manual worm gear (most common for fire signal valves - reliable, no power needed, handwheel operation, self-locking); (b) manual handle (small DN ≤DN100); (c) electric (for remote/automated systems, fast, FACP-controlled); (d) pneumatic/electro-hydraulic (special/large DN); (e) manual primary because fire valves should be operable during power outage (fire may cut power). Test & certification: (a) strength test 1.5×PN (body); (b) seal test 1.1×PN (zero leakage); (c) signal function test - verify switch activation at open/close, contact resistance, signal output; (d) fire code certification - GB/T 5135.6, CCCF (China fire product certification) optional; (e) third-party (BV/SGS/TUV) optional. Important notes: (a) fire water only - not for other media unless specified; (b) -10~80°C - protect from freezing (insulate if <0°C); (c) install in accessible location - must be operable/inspectable (fire code requires accessible); (d) do not paint over signal device/nameplate; (e) signal wiring - use fire-rated cable, connect to FACP supervisory circuit; (f) periodic test - operate valve + verify signal (quarterly/annually per fire code); (g) grooved connection - use correct gasket, lubricate gasket, torque coupling bolts; (h) not for throttling - fully open or closed (fire valves are on-off, not regulation); (i) bidirectional - can install either direction (soft seal). The valve is manufactured under strict quality control with 100% body hydrostatic (1.5×PN), 100% seat leak (1.1×PN, zero), 100% signal function test (switches, 4-20mA if encoder), 100% pressure test, fire code compliance. With an 18-month warranty and OEM/ODM customization (material, size, pressure, connection, drive, signal type, encoder, coating, certification), this valve is a reliable, code-compliant, fire-signal supervisory butterfly valve for modern fire protection water systems.

 

Product Features

 

1.Real-Time Signal Feedback + Supervisory Alarm

High-precision travel switches + linkage mechanism convert real-time fully-open/fully-closed/intermediate valve status to electrical signals (NO/NC dry contacts) transmitted to fire control room/FACP; optional encoder outputs 4-20mA analog for remote visual monitoring. If valve accidentally closed, blocked, or fails, signal change triggers supervisory alarm immediately - prevents "valve closed during fire" (a leading cause of sprinkler failure). Code-compliant supervisory switch per GB/T 5135.6-2018/NFPA 13.

2.Fast Operation for Fire Emergency

Disc rotates 90° for full open/close - manual operation ≤3 seconds (worm gear/handle), electric 1-5 seconds. Quickly opens fire water supply during emergency to gain valuable firefighting time; quickly closes for zonal water cut-off during system maintenance. Much faster than multi-turn gate valves (30-60s+) - critical for fire emergency response.

3.Compact Structure + Narrow-Space Installation

Body length only 1/3-1/2 of same-DN gate valve, lightweight, short face-to-face - ideal for installation in narrow spaces: ceilings, pipe shafts, underground garages, mechanical rooms of high-rise buildings/commercial centers. Greatly improves installation flexibility where space is limited. Wafer/groove options even more compact.

4.Low Flow Resistance + Reliable Water Delivery

Straight-through flow channel; fully open disc parallel to water flow minimizes obstruction. Flow resistance far lower than gate/globe valves - reduces pipeline pressure loss, ensures sufficient water pressure and flow at end sprinklers or fire hydrants (critical for effective fire suppression). Full-bore design for unobstructed water delivery.

5.Bidirectional Zero-Leak Soft Seal + Long Life

Seat: EPDM (water/weathering), NBR (oil/water), PTFE (chemical/corrosive), Viton (high-temp/oil) - excellent elasticity, aging resistance, water resistance. Disc and seat fit closely for bidirectional zero leakage. Ductile iron/cast steel/SS body, plastic-coated/SS disc, SUS410/316/duplex stem, anti-corrosion treatment - service life 8-12 years under normal fire water conditions.

6.Multiple Connections/Drives + Modular Signal + Fire Code

Connections: flange (rigid/high-pressure), wafer (compact/light), groove (grooved coupling - fast install, common in sprinkler systems). Drives: manual (handle/worm gear), electric, pneumatic, electro-hydraulic. Signal component modular - replace without removing entire valve. DN50-400 (2"-16"), PN10/16/25 (150LB/JIS 5K/10K), -10~80°C. Fire red coating. GB/T 5135.6-2018, API 609, BS 5155, DIN 3202, ISO 5752. 18-month warranty, OEM/ODM.

 

Working Principle

 

A Fire Signal Butterfly Valve operates on the principle of a quarter-turn rotating circular disc (butterfly plate) for on-off control of fire water, combined with a signal feedback (supervisory switch) mechanism that converts the disc's rotational position into electrical signals for remote monitoring and alarm - the disc is mounted on a rotating stem; when the disc is parallel to flow (0°), the valve is fully open (fire water flows with low resistance); when the disc is rotated 90° to be perpendicular to flow, the valve is fully closed (disc blocks flow, soft seat seals); a mechanical linkage (cam/gear) on the stem activates high-precision travel switches at preset positions (fully open, fully closed, intermediate), outputting NO/NC electrical signals to the fire alarm control panel (FACP) - if the valve is accidentally closed, blocked, or fails, the signal changes and triggers a supervisory alarm - with fast 90° operation, compact body, low flow resistance, soft seal zero leakage, flange/wafer/groove connection, and manual/electric/pneumatic/electro-hydraulic drive - a code-compliant fire-signal supervisory butterfly valve for fire protection water systems. The valve consists of a body (ductile iron/cast steel/stainless, flange/wafer/groove ends), a circular disc (ductile iron plastic-coated or stainless, on stem), a stem (SUS410/316/duplex, rotating), a soft seat (EPDM/NBR/PTFE/Viton, in body), packing (stem seal), a drive operator (manual handle/worm gear, electric, pneumatic, electro-hydraulic), and a signal feedback unit (travel switches + cam/linkage, optional encoder + 4-20mA). Quarter-turn on-off principle: (1) fully open (0°): disc plane parallel to flow direction - fire water flows through annular space around thin disc; low flow resistance (K~0.2-0.5); (2) fully closed (90°): disc plane perpendicular to flow - disc edge compresses soft seat (EPDM/NBR/PTFE/Viton), seat deforms = bidirectional zero leakage; (3) fire valves = on-off only (fully open or fully closed - NOT throttling, per fire code); (4) 90° rotation = fast (manual ≤3s, electric 1-5s); (5) operator (worm gear/handle/electric) drives stem. Signal feedback (supervisory switch) principle - core feature: (a) mechanical linkage: stem rotation is transferred via gear/cam to signal unit (mounted on gearbox/top); (b) travel switches (micro switches): at preset angular positions (e.g., 0°=fully open, 90°=fully closed), cam lobe activates/deactivates micro switch; (c) switch output: each switch has NO (normally open) and NC (normally closed) dry contacts - voltage-free (user supplies monitoring voltage); (d) wiring to FACP: switches wired to fire alarm control panel supervisory input circuit (or BMS/SCADA); (e) status indication: FACP reads contact state - e.g., valve open = NO contact closed (conductive), valve closed = NO contact open; (f) supervisory alarm: if valve is not in normal open position (closed, partially open, fault), FACP detects contact change → triggers supervisory alarm (distinct sound/indicator - "supervisory" not "fire alarm"); (g) optional encoder: potentiometer/encoder coupled to stem → outputs 4-20mA analog proportional to angle (4mA=0° closed, 20mA=90° open) → precise position on SCADA/BMS graphic display; (h) intermediate signal: some models have switch at intermediate (e.g., 15° from closed) to detect "valve not fully open" (tampering/maintenance); (i) modular: signal unit is separate module - can be replaced without removing valve body. Why supervisory signal is critical (fire safety): (a) #1 cause of automatic sprinkler system failure = control valve accidentally closed (during maintenance, by unauthorized person, negligence) - when fire occurs, water cannot reach sprinklers; (b) ordinary valve = no remote status - must be manually inspected (often missed, quarterly inspection may be too late); (c) supervisory switch = 24/7 remote monitoring - FACP immediately alerts if valve closed - prevents this failure; (d) code requirement: NFPA 13 (US sprinkler standard) requires supervisory devices on all control valves; GB 50084 (Chinese automatic sprinkler code) requires signal valves (信号蝶阀 / 信号闸阀); EN 12845 (European) similar; (e) this valve = code-compliant signal butterfly valve (GB/T 5135.6-2018). Fast operation principle: (a) butterfly = 90° quarter-turn - one quick motion; (b) manual worm gear: handwheel rotates worm → worm gear → stem → 90° in ≤3s (gear ratio optimized for speed + torque); (c) electric: motor + gearbox → 1-5s; (d) vs gate valve: multi-turn (stem rotates many times to lift gate) - 30-60s+ for large DN - too slow for fire emergency; (e) fast = critical for fire (immediate water) and maintenance (fast zonal shut-off). Compact principle: (a) butterfly disc is thin - body is short (disc diameter ≈ pipe ID, body length ~0.5-1× DN); (b) gate valve body length ~2-3× DN (gate chamber + bonnet + stem); (c) butterfly = 1/3-1/2 gate length + lighter; (d) fits narrow spaces (pipe shaft, ceiling, garage) common in high-rise; (e) wafer/groove even shorter. Low flow resistance principle: (a) fully open disc = thin plate parallel to flow - minimal obstruction; (b) K factor ~0.2-0.5 (very low); (c) globe valve K=3-10 (S-shaped path); (d) low resistance = low pressure loss = water pressure/flow preserved to end sprinklers/hydrants; (e) fire code requires minimum residual pressure at remote sprinkler (e.g., 0.05 MPa / 7 psi) - low-resistance valves help meet this. Soft seal zero-leakage principle: (a) EPDM/NBR/PTFE/Viton seat in body bore; (b) disc closes (90°), disc edge compresses soft seat - seat deforms conforms to disc = zero leakage (bubble-tight); (c) bidirectional: seals both flow directions (soft seat on both sides or symmetric); (d) EPDM: water, weathering, ozone, ≤120°C - fire water standard; (e) NBR: oil/water, ≤80°C; (f) PTFE: chemical/corrosive, ≤180°C; (g) Viton: high-temp/oil, ≤200°C; (h) fire water = EPDM most common. Multiple connections: (a) flange: body flanges bolted to pipeline - rigid, high pressure, easy remove, for main pipe/high pressure; (b) wafer: thin body clamped between pipeline flanges with long bolts - compact/light/cheap, for branch/medium; (c) groove (grooved coupling): body has grooved ends, pipe roll-grooved, coupling clamp + gasket connects - very fast installation (no welding/threading), no hot work, easy disconnect - dominant in fire sprinkler systems (Victaulic style); (d) select per pipeline design. Multiple drives: (a) manual handle: small DN ≤DN100, direct lever 90°, simple/no power; (b) manual worm gear: larger DN, worm gear reduces effort, self-locking, handwheel, most common for fire signal valves (reliable, operable during power outage); (c) electric: motor+gearbox, remote/FACP-controlled, fast 1-5s, for automated systems; (d) pneumatic: compressed air, fast, hazardous; (e) electro-hydraulic: high torque, large DN; (f) manual primary for fire (power may fail during fire - manual operability essential). Grooved connection detailed (fire sprinkler): (a) pipe end roll-grooved (cold-formed groove, no cutting); (b) valve end has matching groove; (c) coupling = split metal clamp + rubber gasket; (d) gasket sits over groove, clamp over gasket, bolts tightened → gasket compressed = seal; (e) advantages: fast install (minutes), no welding (no fire hazard during install), flexible (allows some deflection/vibration), easy disconnect (maintenance), pressure-rated (up to PN25); (f) standard in fire sprinkler worldwide (Victaulic, Gruvlok, Mech); (g) this valve offers grooved ends. Fire red coating: (a) fire safety color code: fire valves = red (Ral 3000 or similar) - immediate identification in emergency; (b) ductile iron body → blast clean → epoxy red paint (corrosion-resistant, durable, indoor/outdoor); (c) some regions require red for all fire protection valves; (d) nameplate/signal device not painted over. Testing: (1) body hydrostatic 1.5×PN - zero external leak; (2) seat leak 1.1×PN - zero leakage (soft seal, bubble test); (3) signal function test - verify switch activation at fully open/fully closed, contact resistance (<100mΩ), insulation resistance, 4-20mA output (if encoder); (4) operation test - full open/close, torque, timing; (5) pressure test per GB/T 5135.6/API 609; (6) appearance/coating - red paint thickness/adhesion; (7) marking - size/pressure/material/standard/signal. FACP integration: (a) switch wiring: NO/NC common (COM) - 3-wire per switch (COM, NO, NC) or 2-wire (NO+COM); (b) fire-rated cable: use fire-resistant cable (e.g., LSZH, PH30/PH60/PH120) per code; (c) FACP supervisory module: connect to supervisory input module (not alarm input) - FACP distinguishes supervisory vs fire alarm; (d) monitoring: FACP displays valve status (open/closed) on graphic/text; (e) alarm: if closed when should be open → supervisory alarm (buzzer + print + history); (f) BMS/SCADA: optional via 4-20mA encoder or Modbus. Maintenance (fire code): (a) quarterly: visually inspect valve position (should be open), signal indicator, no leaks; (b) annually: operate valve full open/close, verify signal to FACP, test supervisory alarm (close valve → FACP alarms), lubricate stem, inspect seat; (c) 5-year: replace seat/packing if needed, inspect signal switches; (d) record: all tests logged (fire marshal inspection); (e) never leave valve closed after maintenance without reopening + verifying signal. Important: (a) on-off only - do not use for throttling (partial opening = high velocity/cavitation/seat wear, and fire code requires fully open); (b) fire water - not for other media unless specified; (c) -10~80°C - insulate if ambient <0°C (freezing can damage seat/body); (d) accessible - fire code requires valve accessible for operation/inspection (not buried/blocked); (e) do not paint signal device, nameplate, stem; (f) signal wiring - fire-rated cable, correct polarity; (g) grooved coupling - use correct gasket, lubricate, torque per manufacturer; (h) periodic test mandatory per fire code. Operation: (1) open: rotate handwheel/handle counterclockwise (or electric open) → disc to 0° parallel → signal "open" to FACP; (2) close: rotate clockwise → disc to 90° perpendicular → seat seals → signal "closed" → FACP supervisory alarm (if not expected); (3) indication: local position indicator (open/close) on gearbox; (4) manual override (electric): declutch motor, use handwheel.

 

Application Scenarios

 

• Automatic Sprinkler System

Zonal control valves, control valves in front of alarm valve groups (wet/dry/pre-action), end-of-line test device control valves in automatic sprinkler systems. Signal feedback to FACP ensures valve is open (supervisory alarm if closed); fast operation for zonal maintenance without affecting other areas; low flow resistance ensures sprinkler water pressure; grooved connection for fast sprinkler pipe install. Code-compliant per GB 50084/NFPA 13.

• Fire Hydrant System

Main pipe, branch pipe, and fire pump outlet control valves for indoor/outdoor fire hydrant systems. Fast open ensures rapid water supply during fire fighting; signal monitoring verifies valve ready; compact for building pipe shafts; bidirectional zero leakage maintains system pressure. For high-rise, commercial, industrial hydrant networks.

• High-Rise Buildings + Large Venues

Fire protection systems in high-rise residential, commercial centers, shopping malls, hotels, hospitals, schools, stadiums - compact body fits narrow pipe shafts/ceilings/underground garages; signal feedback to building FACP/BMS for centralized monitoring; fire red coating for easy identification; multiple connection options for diverse piping. Essential for modern building fire safety.

• Industrial + Commercial Facilities

Factories, warehouses, power plants, chemical plants, logistics centers - fire water pipelines with corrosive/dusty conditions; ductile iron/cast steel/stainless body options; EPDM/NBR/PTFE seats; manual worm gear reliable without power; signal alarm for unattended areas; flange/wafer/groove for different pipe standards. Reliable for industrial fire protection.

• Public Infrastructure + Transportation 

Tunnels, airports, railway stations, subway stations, car parks, exhibition centers - large-space fire protection with long pipe runs; low flow resistance preserves end pressure; signal monitoring in central control room; fast emergency operation; compact for tunnel/ceiling installation. 18-month warranty, OEM/ODM customization (size/connection/drive/signal/certification).

 

Quality Assurance

 

Our Fire Signal Butterfly Valves are manufactured under an ISO 9001:2015 certified quality management system, with every valve undergoing rigorous inspection and testing at each production stage - because these fire-signal butterfly valves are life-safety fire protection components used in automatic sprinkler systems, fire hydrant systems, high-rise buildings, and public facilities where valve failure, seal leakage, signal malfunction, or accidental closure can prevent water delivery during a fire, causing property damage and loss of life - fire valves require strict code compliance, body integrity, zero seat leakage, and 100% signal function verification. Raw material control: every body/disc/stem material batch comes with material certificate (chemical + mechanical per heat); ductile iron (GGG40, tensile ≥400MPa), cast steel WCB, stainless SS304/316 verified by PMI; EPDM/NBR/PTFE/Viton seats verified for grade/hardness/aging; signal switches (micro switches, UL/TUV/CE certified components), encoder (if specified) verified; fire-rated cable glands.

Body manufacturing: (a) casting (ductile iron/cast steel/stainless) - sand casting; (b) heat treatment (ductile iron annealing, WCB normalizing/tempering, stainless solution annealing); (c) 100% visual; (d) NDT - radiographic/ultrasonic of critical sections (for large DN); (e) wall thickness (per GB/T 5135.6/API 609); (f) end machining (flange/wafer/groove - groove dimensions per grooved coupling standard); (g) seat recess machining; (h) stem bore/bearing; (i) chemical/mechanical/hardness per heat; (j) surface preparation (blast clean) + fire red epoxy coating (paint thickness 60-100μm, adhesion test, salt spray for outdoor); (k) nameplate (stainless, engraved - size/pressure/material/standard/year).

Disc manufacturing: (a) cast/forged disc; (b) plastic coating (nylon/epoxy, for ductile iron - corrosion-resistant, smooth, low torque) or stainless; (c) disc edge machining (sealing surface); (d) stem hole/keyway; (e) coating adhesion test; (f) dynamic balance.

Seat manufacturing: (a) EPDM/NBR rubber molded (hardness 60-75 Shore A, tensile, aging test, water absorption); (b) PTFE/Viton machined/molded; (c) dimensional check, hardness, compression set; (d) fire water compatibility (EPDM for water).

Stem: (a) SUS410/SUS316/duplex machined; (b) surface treatment (SUS410: hardened; stainless: passivated); (c) dimension check, straightness. Signal unit: (a) travel switches (micro switches) - electrical test (contact resistance, insulation, actuation force); (b) cam/gear machining (position accuracy); (c) encoder (if specified) - 4-20mA calibration; (d) housing (waterproof, IP65/IP67); (e) function test: switch activation at preset angles (0°/90°), signal output, wiring; (f) modular assembly (easy replace).

Assembly: (1) install seat (bonded/inserted); (2) install stem + bearings + packing; (3) install disc (align with stem, key/pin); (4) install operator (worm gear/handle/electric); (5) install signal unit on top - couple cam to stem, set switch positions (fully open/fully closed), wiring; (6) full stroke test (0-90°, smooth); (7) signal calibration: set NO/NC at fully open (0°) and fully closed (90°) - verify contact change; (8) encoder calibration (4mA=closed, 20mA=open); (9) local position indicator set.

Pressure testing: (1) 100% body hydrostatic shell 1.5×PN - zero external leak; (2) 100% seat leak 1.1×PN - zero leakage (soft seal, bubble test, bidirectional); (3) 100% air tightness (low-pressure air); (4) strength + seal per GB/T 5135.6-2018 / API 609. Signal function testing (100% - critical for fire valves): (1) switch activation: rotate valve from closed→open - verify "open" switch activates at 0° (±2°); rotate open→closed - verify "closed" switch at 90° (±2°); (2) contact output: measure NO/NC contact resistance (<100mΩ when closed, >100MΩ when open), insulation resistance (>500MΩ@500VDC); (3) alarm simulation: close valve → verify signal change (simulates FACP alarm); (4) encoder (if specified): 4-20mA output linearity, span/zero, accuracy ≤±1%; (5) wiring/cable gland: waterproof test; (6) signal label: wiring diagram on housing.

Function testing: open/close torque, 90° travel, disc position, end dimensions (flange/wafer/groove), face-to-face, seat sealing, operator function (manual/electric), signal function, coating thickness/adhesion, nameplate marking, fire red color, grooved end dimensions (if groove).

Fire code compliance: (a) GB/T 5135.6-2018 (fire signal butterfly valve) - design/test/marking; (b) GB 50084 (automatic sprinkler) - signal valve requirement; (c) CCCF (China fire product certification) optional; (d) NFPA 13 (US) supervisory switch; (e) third-party fire test (if required).

Coating & marking: exterior - fire red epoxy (Ral 3000 or customer red), interior - epoxy for water; valve permanently marked with DN, PN, material, standard (GB/T 5135.6), open/close direction, signal wiring, manufacturer, year; nameplate (stainless, corrosion-resistant); signal unit has wiring diagram label.

Documentation: shipped with hydrostatic test report, material certificate, seat leak report, signal function test report (switch calibration, 4-20mA if encoder), installation/operation/maintenance manual (including FACP wiring, signal wiring diagram, fire code requirements, periodic testing), fire code compliance certificate (if applicable), wiring diagram.

Warranty: 18 months from shipment or 12 months from installation (valve body); signal unit/electric actuator 12 months; extended warranty and third-party inspection (BV, SGS, TUV) and CCCF fire certification available.

 

FAQ

 

Q: What is a fire signal butterfly valve, and why is signal feedback required for fire sprinkler systems?

A: A fire signal butterfly valve (also called supervisory butterfly valve or signal butterfly valve) is a butterfly valve equipped with a supervisory switch (signal feedback device) specifically designed for fire protection water systems (automatic sprinkler, fire hydrant). It combines: (a) butterfly valve on-off (disc rotates 90° to open/close fire water); (b) signal feedback - high-precision travel switches convert the valve's real-time open/close status into electrical signals (NO/NC dry contacts) sent to the fire alarm control panel (FACP) or building management system (BMS), so the fire control room can remotely monitor valve status without manual inspection; (c) supervisory alarm - if the valve is accidentally closed, blocked, or fails, the signal changes and triggers an alarm. Why signal feedback is required: (a) #1 cause of automatic sprinkler system failure = control valve accidentally closed (during maintenance, by unauthorized person, or negligence) - when a fire occurs, water cannot reach the sprinklers, so the system fails; (b) ordinary valve (no signal) requires manual on-site inspection (often quarterly) - a valve could be closed for months before being discovered, creating a major fire hazard; (c) supervisory switch provides 24/7 remote monitoring - FACP immediately alerts if valve is not in normal open position (supervisory alarm), preventing this failure; (d) code requirement: NFPA 13 (US automatic sprinkler standard) requires supervisory devices on all control valves in sprinkler systems; GB 50084 (Chinese automatic sprinkler code) requires signal valves (信号蝶阀 / 信号闸阀) on sprinkler piping; EN 12845 (European) has similar requirements; (e) insurance requirement: many insurers require supervised valves for premium discounts. How it works: (a) travel switches (micro switches) mechanically linked to valve stem; (b) when valve fully open → "open" switch activated → FACP shows "normal/open"; (c) when valve closed (even partially) → switch deactivates → FACP detects change → supervisory alarm (distinct from fire alarm - indicates "system impairment, not fire"); (d) optional encoder outputs 4-20mA for precise position/visual display. Butterfly vs gate for fire signal: (a) fire signal butterfly valve (this valve): 90° fast (≤3s manual), compact/short/light (fits narrow pipe shafts/ceilings), low cost, low flow resistance - dominant in modern high-rise fire systems; (b) fire signal gate valve: multi-turn slow (30-60s), bulky/long/heavy, higher cost - older style, less common now; (c) butterfly preferred for new installations. This valve is code-compliant (GB/T 5135.6-2018, API 609), with signal feedback, fast operation, compact design - ideal for modern fire protection. Note: (a) fire signal valves are normally open (fully open during normal operation - water ready); (b) only closed during maintenance/emergency; (c) signal monitors "is it open?" - if not, alarm.

 

Q: How does the signal feedback (supervisory switch) work, and how do I wire it to the fire alarm panel?

A: Signal feedback mechanism: (a) mechanical linkage: valve stem rotation is transferred via gear/cam to the signal unit (mounted on top of gearbox/operator); (b) travel switches (micro switches): at preset angular positions (typically 0° = fully open, 90° = fully closed), a cam lobe activates or deactivates a micro switch; (c) switch contacts: each micro switch has 3 terminals: COM (common), NO (normally open), NC (normally closed) - these are dry contacts (voltage-free, no internal power); (d) when switch activated (e.g., valve open), NO closes (conductive) and NC opens; when deactivated (valve closed), NO opens and NC closes; (e) optional encoder: potentiometer/encoder coupled to stem → outputs 4-20mA analog proportional to angle (4mA = 0° closed, 20mA = 90° open) for precise position. Wiring to FACP (Fire Alarm Control Panel): (1) identify switch type: usually 2 switches (open + closed) or 1 switch (open/close); each has COM/NO/NC; (2) use fire-rated cable: fire-resistant cable (e.g., LSZH low-smoke zero-halogen, PH30/PH60/PH120, or fire-rated shielded) per local fire code - cable must survive fire for specified time; (3) connect to FACP supervisory module: NOT fire alarm input - use supervisory input module (monitor module) - FACP distinguishes "supervisory" (valve impairment) from "fire alarm"; (4) wiring example (open supervision): (a) FACP supervisory module has 2 terminals (IN+, IN-); (b) connect FACP IN+ → valve switch COM; (c) connect valve switch NO (for "valve open = circuit closed") → FACP IN-; (d) when valve open → NO closed → FACP sees continuity = "normal"; (e) when valve closed → NO open → FACP sees open circuit → supervisory alarm; (5) or use NC (some prefer NC = fail-safe - wire break also alarms); (6) end-of-line resistor (EOL) - FACP supervisory circuits often require EOL resistor (e.g., 47kΩ) at last device to detect wire break; (7) multiple valves: each valve on separate supervisory input (or addressable module) - FACP identifies which valve; (8) encoder (4-20mA): connect to PLC/BMS analog input (4-20mA), power supply (24VDC) for 2-wire loop; (9) ground/shield: shielded cable - drain wire grounded at one end (FACP) to prevent noise. FACP programming: (a) configure input as supervisory (not alarm); (b) set device label (e.g., "Sprinkler Zone 3 Control Valve"); (c) set alarm type (supervisory - latching, requires reset); (d) test: close valve → FACP shows supervisory alarm with device label; (e) history/logging. Verification test: (a) after wiring, operate valve closed → verify FACP alarms (correct device, supervisory type); (b) open valve → verify FACP returns to normal; (c) test wire break (disconnect wire) → FACP should alarm (trouble/supervisory); (d) record test (fire marshal may inspect). Important: (a) consult FACP manufacturer for exact module/wiring (addressable vs conventional); (b) do not power switches directly - they are dry contacts (FACP provides monitoring voltage); (c) waterproof cable gland on valve signal housing (IP65/IP67); (d) label wires at both ends; (e) do not run signal cable parallel to power cable (interference) - separate conduit; (f) periodic test (quarterly/annual) - verify signal to FACP. This valve comes with wiring diagram label on signal unit and in manual - follow for exact terminal assignments.

 

Q: What connection type should I choose - flange, wafer, or groove (grooved)?

A: Flange connection: Valve body has integral flanges at both ends - bolted directly to pipeline flanges with gasket. Advantages: (a) rigid/strong - suitable for higher pressure (PN25), main pipes, large DN; (b) easy install/removal - unbolt flanges, valve removed without cutting pipe; (c) standard - matches common pipeline flanges (GB/DIN/ANSI/JIS); (d) can support pipe weight. Disadvantages: (a) heavier/costlier than wafer; (b) longer than wafer. Use for: main fire water pipes, high pressure (PN25), large DN (≥DN200), where valve removal for maintenance needed. Wafer connection: Thin body, no flanges - valve is clamped between two pipeline flanges using long bolts passing through valve body. Advantages: (a) very compact/light/cheap; (b) short face-to-face; (c) easy for small/medium DN. Disadvantages: (a) less rigid - not for high pressure/large DN; (b) requires long bolts (span both flanges + valve); (c) harder to install (align all long bolts); (d) cannot remove valve without disconnecting pipeline (bolts through both flanges). Use for: branch pipes, low/medium pressure (PN10/16), small/medium DN (≤DN150), cost-sensitive, compact spaces. Groove (grooved coupling) connection: Valve body has grooved ends (roll-groove profile); pipe ends are roll-grooved (cold-formed groove); a grooved coupling clamp (split metal clamp + rubber gasket) connects valve to pipe. Advantages: (a) very fast installation (minutes - no welding, no threading); (b) no hot work (no fire hazard during installation - important in buildings); (c) flexible - allows some angular deflection, vibration, expansion; (d) easy disconnect (loosen clamp, remove - for maintenance); (e) pressure-rated (up to PN25); (f) dominant in fire sprinkler systems worldwide (Victaulic, Gruvlok, Mech style). Disadvantages: (a) requires grooved pipe + couplings (additional parts); (b) slightly larger OD than flange; (c) not for very high pressure (>PN25). Use for: fire sprinkler branch lines (most common), commercial buildings, fast-track projects, where no welding allowed. Selection guide: (a) sprinkler branch pipes, fast install, no welding → groove (most popular for fire sprinkler); (b) main pipe, high pressure, large DN, removable → flange; (c) small branch, low pressure, cost-sensitive, compact → wafer; (d) match existing pipeline - if pipeline is grooved → groove valve; if flanged → flange; (e) DN ≤DN150 → wafer/groove; DN ≥DN200 → flange/groove; (f) PN25 → flange/groove (not wafer). This valve offers all three - specify when ordering. Note: (a) grooved connection requires correct gasket (EPDM for fire water, NBR for oil), lubricate gasket (silicone grease, not petroleum-based), torque coupling bolts per manufacturer (usually 25-40 Nm depending on size); (b) flange gasket - spiral wound or rubber (EPDM) for fire water; (c) wafer - use ring gaskets + long bolts (grade matching pressure); (d) grooved couplings are standardized (Victaulic Style 77/99, etc.) - verify compatibility.

 

Q: Manual vs electric drive for fire signal butterfly valve - which is standard for fire systems?

A: Manual worm gear (standard for fire signal valves): Handwheel + worm gearbox drives stem 90°. Advantages: (a) no power required - operable during power outage (fire often causes power loss - manual operability critical); (b) reliable/simple - no motor/electronics to fail; (c) self-locking (worm gear holds position); (d) labor-saving (gear reduces effort for large DN); (e) cost-effective. Disadvantages: (a) not remote-controlled (must go to valve); (b) slower than electric (but ≤3s still fast). Use for: most fire signal valves - building sprinkler/hydrant control valves (normally open, rarely operated, must work during power failure). Manual handle (small DN): Direct lever handle for DN ≤DN100 - simplest, fastest, no power. Electric actuator: Motor + gearbox, remote-controlled via FACP/PLC or switch. Advantages: (a) remote operation - open/close from control room (no site visit); (b) fast (1-5s); (c) automated - can interlock with fire alarm (e.g., auto-open on fire signal, auto-close for zonal); (d) position feedback built-in. Disadvantages: (a) requires power - during power outage, may not operate (unless battery backup/ups); (b) more complex/costly (motor, gearbox, controller); (c) must have manual override (handwheel/crank for power failure - required by fire code); (d) fire code may require manual operability. Use for: automated fire systems, large DN, remote locations, where remote operation needed (e.g., pre-action sprinkler, deluge, special hazard). Pneumatic/electro-hydraulic: For special/large DN, hazardous areas - less common for standard building fire. Which is standard for fire systems? Manual worm gear is the standard/most common for fire signal butterfly valves because: (a) fire code emphasizes reliability during power failure - manual always works; (b) fire control valves are normally open and rarely operated (only maintenance/emergency) - no need for frequent remote operation; (c) signal feedback (not remote operation) is the key requirement - manual valve + signal switch = FACP monitors status, which is what code requires; (d) lower cost, less maintenance. Electric is used when: (a) remote operation required (e.g., pre-action/deluge systems that auto-open on fire alarm); (b) valve in inaccessible location; (c) large DN where manual effort too high; (d) integrated with building automation. Important: (a) if electric, must have manual override (handwheel/crank) per fire code - for power failure; (b) UPS/battery backup for electric fire valves (if required); (c) signal switch works regardless of drive (manual or electric - signal monitors position); (d) this valve offers manual (handle/worm gear) standard, electric/pneumatic/electro-hydraulic optional - specify. Recommendation: for standard building sprinkler/hydrant control valves → manual worm gear + signal feedback (code-compliant, reliable, cost-effective); for automated/special systems → electric + manual override + signal.

 

Q: What maintenance and periodic testing are required for fire signal butterfly valves?

A: Fire signal butterfly valves are life-safety devices - regular maintenance and testing are required by fire code (NFPA 25, GB 50261, etc.) and essential for reliability. Periodic inspection/testing schedule: Monthly/Quarterly: (1) visual inspection: verify valve in fully open position (indicator, handwheel position); (2) signal status: check FACP shows "normal/open" (no supervisory alarm); (3) no leaks (body, flange/groove, stem); (4) accessible (not blocked, not painted over, nameplate/signal device legible); (5) no damage (handle, signal housing, wiring). Annually (minimum): (1) full operational test: operate valve full close → full open (verify smooth, no binding, ≤3s manual); (2) signal test: while closing, verify FACP supervisory alarm triggers (correct device label, supervisory type); while opening, verify FACP returns to normal; (3) seat leak test: after close, verify no leakage through valve (visual/listen); (4) stem lubrication: lubricate stem/bearing with anti-seize (especially if rarely operated); (5) fastener check: tighten flange/groove coupling bolts if needed; (6) wiring check: inspect signal cable (no damage, waterproof gland tight, labels); (7) coating: touch up paint chips (prevent corrosion); (8) record: log all tests (date, result, technician) - fire marshal/insurance may inspect records. Every 3-5 years: (1) seat inspection/replacement: if leakage, wear, cracking, permanent set - replace seat (EPDM/NBR/PTFE/Viton ages over time); (2) packing replacement: if stem leaks; (3) signal switch inspection: clean, verify contact, replace if worn; (4) disc inspection: check plastic coating (if ductile iron coated) - touch up chips; (5) groove gasket (if grooved) - replace if compressed/cracked. After maintenance/repair: (1) reopen valve fully (critical - do not leave closed); (2) verify signal "open" at FACP; (3) pressure test (if seat replaced - 1.1×PN); (4) update records. Common maintenance issues: (a) valve seized (not operated for years) - lubricate stem, exercise gently (do not force - may break stem); (b) seat leak - seat worn/deformed (replace), or disc not fully closed (calibrate stop); (c) signal false alarm - switch misadjusted (recalibrate at 0°/90°), wiring loose, FACP programming error; (d) no signal - wiring break, switch failed, FACP module fault; (e) groove leak - gasket failed, coupling loose (retorque/replace gasket); (f) corrosion - paint chip (touch up), harsh environment (consider stainless body). Fire code requirements: (a) NFPA 25 (US): control valves inspected quarterly (visual), tested annually (operate + signal); (b) GB 50261 (China): sprinkler system maintenance - valves inspected monthly, tested annually; (c) records retained 3-5 years (per jurisdiction); (d) tagging: valve should have identification tag (zone, system, last test date); (e) only qualified personnel perform testing. Important: (a) never leave valve closed after testing/maintenance - always reopen + verify FACP signal; (b) notify building occupants/FACP before testing (supervisory alarm may trigger - put system in test mode); (c) do not paint signal device, nameplate, stem, wiring; (d) spare parts: keep seat, packing, signal switch, gasket for critical valves; (e) replace valve if body corroded, stem damaged, repeated failure - typically 8-12 year life (may extend with maintenance). This valve is designed for easy maintenance - modular signal unit (replace without removing valve), accessible stem, standard seats. With proper periodic testing, it will provide reliable fire protection for 8-12+ years.

 

Q: Can this valve be used for media other than fire water, and what are the temperature/pressure limits?

A: Primary use = fire water - this valve is designed and certified for fire protection water systems (automatic sprinkler, fire hydrant) with water as the medium. Temperature range: -10°C ~ 80°C (standard): (a) lower limit -10°C: fire water systems are typically indoor/heated (above freezing); if ambient below 0°C, valve/pipe must be insulated/heat-traced (freezing water expands and can crack body/seat); (b) upper limit 80°C: EPDM seat rated ≤120°C, but fire water is typically ambient (<40°C); 80°C covers warm water/hot water systems; (c) for >80°C: use Viton seat (≤200°C) or PTFE (≤180°C) - specify; (d) for <-10°C: special low-temp seat/body (not standard). Pressure range: PN10/16/25 (1.0/1.6/2.5MPa, 150LB, JIS 5K/10K): (a) standard fire systems are PN10/16 (most common); (b) PN25 for high-rise/high-pressure; (c) not for >PN25 (use gate/ball for higher). Other media (optional, with correct seat/material): (a) water (primary - fire water, domestic water, cooling water) - EPDM seat; (b) oil (light oil, lubricating oil) - NBR (nitrile) seat (EPDM swells in oil - do not use EPDM for oil); (c) gas (air, natural gas, inert gas) - EPDM/NBR (verify pressure/temp); (d) chemical/corrosive (acids, alkalis, mild corrosive) - PTFE seat + stainless body (not ductile iron); (e) hot water/oil (up to 200°C) - Viton seat; (f) NOT for: steam (high temp >200°C, use hard-seal valve), strong solvents (check PTFE compatibility), abrasive slurry (wears seat fast), high pressure >PN25, cryogenic. Material options for other media: (a) ductile iron body (standard) - water, non-corrosive; (b) cast steel WCB - oil/gas, higher pressure; (c) stainless SS304/316 - corrosive, chemical, food; (d) disc: ductile iron plastic-coated (water, corrosion-resistant) or stainless (corrosive); (e) stem: SUS410 (general), SUS316 (corrosion), duplex (high strength/corrosion). If you need non-fire-water media: (a) specify medium + temp + pressure when ordering - we configure seat/body/material accordingly; (b) note: signal feedback still works regardless of medium; (c) fire red coating may not be appropriate for non-fire use (can change color); (d) fire certification (CCCF) only for fire water use. Important: (a) standard valve = EPDM seat + ductile iron body = fire water only - do not use for oil (EPDM swells) or corrosive (ductile iron rusts); (b) EPDM vs NBR: EPDM = water/weathering/ozone (NOT oil/hydrocarbon); NBR = oil/water (NOT ozone/weathering as good); (c) PTFE = chemical/corrosive (but higher torque, not zero leakage like soft rubber); (d) Viton = high-temp/oil (expensive); (e) verify compatibility - if unsure, consult chemical resistance chart or us; (f) for fire water (95% of applications), standard EPDM + ductile iron is correct and code-compliant. This valve is primarily a fire water signal valve - for other media, specify and we will customize seat/body/material to suit.

 

Hot Tags: Fire Signal Butterfly Valve | DN50-400 Supervisory Switch Factory, China Fire Signal Butterfly Valve | DN50-400 Supervisory Switch Factory manufacturers, suppliers, factory, triple offset butterfly valve, 5 inch butterfly valve, 1 inch butterfly valve, 14 butterfly valve, bf valve 2023, high performance butterfly valves

Item Specifications
Product Name Fire Signal Butterfly Valve (Supervisory Signal Butterfly Valve, Fire Protection Signal Butterfly Valve)
Valve Type Quarter-turn butterfly valve with supervisory signal feedback (travel switches) - specialized for fire protection water systems; disc rotates 90° on-off; signal converts open/close status to electrical for fire control room
Disc Design Circular disc (butterfly plate) on rotating stem; concentric; ductile iron plastic-coated or stainless
Stem Design Rotating stem (SUS410/SUS316/duplex), coupled to operator and signal cam
Signal Feedback High-precision travel switches (micro switches) + cam/linkage - outputs NO/NC dry contacts at fully open (0°) and fully closed (90°); optional encoder 4-20mA analog for precise position/remote visual; supervisory alarm on accidental close/block/failure
Nominal Diameter DN50–DN400 (2"–16")
Nominal Pressure PN10, PN16, PN25 (1.0/1.6/2.5 MPa); Class 150 (150LB); JIS 5K/10K
Operating Temperature -10°C ~ 80°C (standard, fire water); Viton seat optional to 200°C, PTFE to 180°C
Applicable Medium Water (primary - fire water, sprinkler, hydrant), oil (NBR seat), gas, mild chemical (PTFE seat, stainless body)
Connection Mode Flange Connection, Wafer Connection, Groove (Grooved Coupling) Connection
Flange Standard GB/T 9113, DIN EN 1092, ASME B16.5, JIS B2220
Groove Standard Grooved coupling (Victaulic style, roll-groove pipe)
Flow Direction Bidirectional (soft seal)
Rotation Angle 0° ~ 90° (quarter-turn on-off)
Flow Characteristic Quick-opening (on-off only - fully open or closed, not for throttling per fire code)
Flow Resistance K factor ~0.2-0.5 (fully open, low resistance - ensures sprinkler/hydrant end pressure)
Control Mode On-off (fully open/fully closed) with signal feedback; not for regulation/throttling
Sealing Type Soft seal - EPDM, NBR, PTFE, Viton (disc compresses seat, bidirectional zero leakage)
Sealing Grade Zero leakage (bubble-tight, soft seal) per GB/T 5135.6/API 598
Signal Output Switch Signal: NO/NC dry contacts (COM/NO/NC per switch), voltage-free; Analog Signal: 4-20mA (optional encoder)
Signal Switch Accuracy ±2° (activation at fully open/fully closed)
Signal Housing Protection IP65 standard, IP67 optional
Operation Time Manual: ≤3 seconds (worm gear/handle); Electric: 1-5 seconds
Driving Mode Manual (handle for small DN, worm gear handwheel standard), Electric (optional, with manual override), Pneumatic (optional), Electro-hydraulic (optional)
Electric Actuator Power AC220V/AC380V/DC24V (if electric)
Valve Body Material Ductile Iron (GGG40, standard), Cast Steel (WCB), Stainless Steel (SS304/SS316)
Disc Material Ductile Iron with Plastic (nylon/epoxy) Coating, Stainless Steel (SS304/SS316)
Valve Stem Material SUS410 (13Cr), SUS316, Duplex Stainless Steel
Seat Material EPDM (water/weathering, ≤120°C), NBR (oil/water, ≤80°C), PTFE (chemical/corrosive, ≤180°C), Viton (high-temp/oil, ≤200°C)
Packing Material PTFE, Graphite, EPDM
Body Gasket EPDM/rubber (flange/wafer), Grooved coupling gasket (EPDM/NBR)
Body Coating Fire red epoxy paint (Ral 3000 or customer red), exterior; interior epoxy for water; stainless pickled/passivated
Strength Test Pressure 1.5 × nominal pressure (hydrostatic shell)
Sealing Test Pressure 1.1 × nominal pressure (seat, zero leakage)
Design Standard GB/T 5135.6-2018 (fire signal butterfly valve), API 609, BS 5155, DIN 3202, ISO 5752
Face-to-Face Standard GB/T 12221, ISO 5752, API 609, BS 5155
Test Standard GB/T 13927, API 598, GB/T 5135.6-2018
Testing Performed 100% body hydrostatic (1.5×PN), seat leak (1.1×PN, zero), air tightness, signal function (switch activation at 0°/90°, NO/NC contact, 4-20mA if encoder), operation test (torque/timing), flange/wafer/groove dimension, coating, NDT for large DN; optional fire certification
Fire Code Compliance GB/T 5135.6-2018, GB 50084 (sprinkler), NFPA 13 (supervisory switch); CCCF fire certification optional
Material Certificate EN 10204-3.1 optional; third-party 3.2 optional
Certification ISO 9001, CE; CCCF (China fire product) optional; WRAS/NSF drinking water optional
Installation Orientation Any orientation (recommend accessible for operation/inspection per fire code; stem horizontal/operator accessible)
Spare Parts Seat ring (EPDM/NBR/PTFE/Viton), disc, stem, packing, gasket, signal switch unit, encoder, grooved coupling gasket, operator repair kit
Optional Features Electric/pneumatic/electro-hydraulic actuator, 4-20mA encoder, IP67 signal housing, stainless body/disc, Viton/PTFE/NBR seat, grooved connection, CCCF fire certification, special coating/color, extended stem, position indicator, fire-rated cable
Warranty 18 months from shipment or 12 months from installation (valve body); signal unit/electric actuator 12 months
Send Inquiry