1. Structural Design Requirements
Gate Valve Structure
Rigid or elastic single-disc gate plates required. Rigid plates for DN100 and below; elastic plates for DN150 and above.
Valve stem and disc connection must ensure smooth opening under full pressure differential.
Globe Valve Structure
Linear flow path design.
Check Valve Structure
Leak-free design. For flammable media, dual-plate check valves must adopt "non-fixed bolt" design or threaded fixed plugs with seal welding.
2. Stem and Bonnet Design
Stem Design
OS&Y (Outside Screw & Yoke) structure required for gate and globe valves. Yoke material must match valve body.
Extended stems must include live-loaded compression (spring force) to withstand actuator load, with anti-blowout design.
Bonnet Design
Bolted, welded, or integral bonnet (for DN50 and below). Forged valve bolts must comply with ASME 18.2.1.
Extended bonnet neck must meet vaporization space requirements.
Cryogenic gate/globe valves require upper seals near packing, with sealing surfaces welded with austenitic stainless steel or hard alloys.
3. Seat and Material Requirements
Seat Design
Elastic seats must resist rapid decompression. Sealing surfaces of closure components and seats require hard alloy overlay (≥1.6mm thickness). Deep cryogenic treatment mandatory for temperatures below -100℃.
Material Selection
Metal seat hardness: Disc surface material must be softer than seat.
Stainless steel carbon content ≤0.23%; copper alloys prohibited.
Austenitic stainless steel must be supplied in solution-treated state.
Bolts/nuts for internals must match valve body chemistry.
Graphite packing: Corrosion-resistant pure graphite (≥99.8% purity).
ASTM A320 B8M "Class 2" bolts required. PMI documentation mandatory for alloy valves.
Austenitic cast valves for ultra-low temperatures require impact testing.
4. Anti-static and Fire-safe Design
Anti-static Design
Elastic-seated valves require conductive paths (valve body, disc, stem) with resistance <10Ω.
Fire-safe Design
API 607 compliance required, except for rubber-lined valves.
5. Operating Torque and Locking
Opening Torque
Handwheel/lever force ≤350N at half-open position; ≤360N under cryogenic conditions.
Valve Locking
Locking devices required at fully open/closed positions.
6. Performance Requirements
Test Certificates
Mandatory for valves of identical type, structure, and size.
Operational Reliability
Smooth operation in all positions for ≥5 years.
7. Welding and NDT Requirements
Casting Valves
Class 900+ stainless steel: 100% RT.
Class 600+ stainless steel: 100% MT/PT.
Forged Valves
Class 600+ stainless steel: 100% MT/PT.
Batch Testing
10% per batch (minimum 1 unit) for others.
Welded Ends
100% X-ray + liquid penetrant testing.
Post-weld Inspection
100% PT for seat surfaces (e.g., 13% Cr/hard alloy overlays).
8. Pressure and Leakage Testing
Sequence
Post-weld heat treatment → NDT → valve cycling → pressure testing (including body strength).
Leakage Tests
High-pressure (1.1×PN), low-pressure (0.2MPa), and stem seal tests.
External Closure Valves
High-pressure seat test (1.1×pressure class).
General Testing
10% of valves (excluding check valves) undergo 1.1× air pressure test. Leakage limits per ISO 5208/ISO 15848-1.
9. Cryogenic Testing
Post-ambient testing, perform:
Ultra-low temperature (-196℃) sealing/leakage tests.
Functional testing (operational torque verification).
Cryogenic sealing (packing, flange gaskets, seats) under maximum working pressure (-20℃ to +38℃).
Cryogenic cycle life testing.