‌1. Structural Design Requirements‌

‌Gate Valve Structure‌

Rigid or elastic single-disc gate plates required. Rigid plates for DN100 and below; elastic plates for DN150 and above.

Valve stem and disc connection must ensure smooth opening under full pressure differential‌.

‌Globe Valve Structure‌

Linear flow path design‌.

‌Check Valve Structure‌

Leak-free design. For flammable media, dual-plate check valves must adopt "non-fixed bolt" design or threaded fixed plugs with seal welding‌.

‌

2. Stem and Bonnet Design‌

‌Stem Design‌

OS&Y (Outside Screw & Yoke) structure required for gate and globe valves. Yoke material must match valve body.

Extended stems must include live-loaded compression (spring force) to withstand actuator load, with anti-blowout design‌.

‌Bonnet Design‌

Bolted, welded, or integral bonnet (for DN50 and below). Forged valve bolts must comply with ASME 18.2.1‌.

Extended bonnet neck must meet vaporization space requirements.

Cryogenic gate/globe valves require upper seals near packing, with sealing surfaces welded with austenitic stainless steel or hard alloys‌.

‌

3. Seat and Material Requirements‌

‌Seat Design‌

Elastic seats must resist rapid decompression. Sealing surfaces of closure components and seats require hard alloy overlay (≥1.6mm thickness). Deep cryogenic treatment mandatory for temperatures below -100℃‌.

‌Material Selection‌

Metal seat hardness: Disc surface material must be softer than seat.

Stainless steel carbon content ≤0.23%; copper alloys prohibited.

Austenitic stainless steel must be supplied in solution-treated state.

Bolts/nuts for internals must match valve body chemistry.

Graphite packing: Corrosion-resistant pure graphite (≥99.8% purity).

ASTM A320 B8M "Class 2" bolts required. PMI documentation mandatory for alloy valves.

Austenitic cast valves for ultra-low temperatures require impact testing‌.

‌

4. Anti-static and Fire-safe Design‌

‌Anti-static Design‌

Elastic-seated valves require conductive paths (valve body, disc, stem) with resistance <10Ω‌.

‌Fire-safe Design‌

API 607 compliance required, except for rubber-lined valves‌.

 

‌5. Operating Torque and Locking‌

‌Opening Torque‌

Handwheel/lever force ≤350N at half-open position; ≤360N under cryogenic conditions‌.

‌Valve Locking‌

Locking devices required at fully open/closed positions‌.

 

‌6. Performance Requirements‌

‌Test Certificates‌

Mandatory for valves of identical type, structure, and size‌.

‌Operational Reliability‌

Smooth operation in all positions for ≥5 years‌.

 

‌7. Welding and NDT Requirements‌

‌Casting Valves‌

Class 900+ stainless steel: 100% RT.

Class 600+ stainless steel: 100% MT/PT‌.

‌Forged Valves‌

Class 600+ stainless steel: 100% MT/PT‌.

‌Batch Testing‌

10% per batch (minimum 1 unit) for others‌.

‌Welded Ends‌

100% X-ray + liquid penetrant testing‌.

‌Post-weld Inspection‌

100% PT for seat surfaces (e.g., 13% Cr/hard alloy overlays)‌.

 

‌8. Pressure and Leakage Testing‌

‌Sequence‌

Post-weld heat treatment → NDT → valve cycling → pressure testing (including body strength)‌.

‌Leakage Tests‌

High-pressure (1.1×PN), low-pressure (0.2MPa), and stem seal tests‌.

‌External Closure Valves‌

High-pressure seat test (1.1×pressure class)‌.

‌General Testing‌

10% of valves (excluding check valves) undergo 1.1× air pressure test. Leakage limits per ISO 5208/ISO 15848-1‌.

 

‌9. Cryogenic Testing‌

Post-ambient testing, perform:

Ultra-low temperature (-196℃) sealing/leakage tests.

Functional testing (operational torque verification).

Cryogenic sealing (packing, flange gaskets, seats) under maximum working pressure (-20℃ to +38℃).

Cryogenic cycle life testing‌.

Send Inquiry