Introduction Lattice structures are cellular materials and have attracted much attention in the field of tissue engineering because they can replicate the morphology and mechanical properties of natural bones. Key design parameters, such as porosity, surface area, and pore size, are of great significance in balancing mechanical integrity and biocompatibility. An ideal bone scaffold should have the same mechanical properties as natural bones, and the MDFG scaffolds fabricated by LPBF make this goal possible. This study systematically evaluated the MDFG scaffolds fabricated by LPBF (covering different types of lattice structures) to determine their applicability in orthopedic applications.
Materials and Methods The scaffolds were modeled using nTopology software. A cube with a unit size of 20 mm was set, and a solid volume layer was added to simulate physiological load conditions. Different unit sizes and seed points were set for different types of lattice structures to create a controllable porosity gradient. The scaffolds were fabricated by LPBF, printing settings were carried out, and specimens were taken out. High - cycle fatigue (HCF) tests were carried out under compression - compression loading conditions, and an appropriate load cell was selected.
Results The quasi - static compression tests showed that the Gyroid and Primitive lattice structures had excellent mechanical properties, and their force - displacement curves showed a typical three - stage deformation process. Finite - element analysis simulations provided an important basis for understanding stress distribution, etc., and the simulation results were highly consistent with the experimental results. By comparing the fatigue - failed specimens of different scaffolds, it was found that the Gyroid lattice had the best overall performance, the long - term performance of the Primitive lattice was better than that of the Voronoi lattice, and the Kelvin mesh had the most stable fatigue resistance.
Conclusions The MDFG scaffolds, especially the Gyroid and Primitive lattice structures, exhibited excellent mechanical and fatigue properties and were an ideal choice for load - bearing orthopedic implants. Advances in scaffold design improved stress distribution, etc., and post - processing techniques were crucial for improving mechanical properties. Future research should explore patient - specific lattice optimization and in - vivo studies to further improve the performance of orthopedic implants and the success rate of clinical applications. In conclusion, the MDFG Ti6Al4V scaffolds fabricated by LPBF have broad application prospects in the field of orthopedic implants. Through continuous research and improvement, it is expected to provide better treatment options for patients.